High Purity Separated Oxides Generated from PLS (updated)
Released
Released
Announcement PDF
ASX Announcement
Released 12th January 2026
https://braziliancriticalminerals.com/
Investor Hub: signup here
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: MINERAÇÃO BBX DO BRASIL LTDA, Rua dos Inconfidentes n⁰ 867, Savassi, Belo Horizonte, Minas Gerais, CEP 30.140-128
Page | 1
EMA FIELD TRIAL REE SOLUTIONS GENERATE
HIGH PURITY SEPARATED OXIDES
Rare Earth Technologies Inc (RETi) has successfully upgraded the Ema field pregnant
liquor solution grade (PLS) 200 times prior to producing cleanly separated individual
REE oxides of high purity
Highlights
• PLS Upgrade: Achieved a 200× upgrade in rare earth concentration from 930
ppm to 186,000 ppm (18.6%) TREO-Ce, utilising RETi’s proprietary processing
equipment and expertise developed in Cincinnati, USA
• 100% Recovery: Enrichment was achieved with no loss of rare earth elements,
concentrating all REEs into a small acid volume
• High-Purity Oxides: The system cleanly separated all major rare earth oxides
into individual products over a 24-minute cycle time, achieving minimum 99.9%
purity for each oxide
• Commercially Proven Technology: The separation system is currently in
commercial use in Europe, offering a simple, automated process with low
chemical consumption and high REE enrichment efficiency
• Superior Processing Advantage: The technology is technically superior for
recovering and separating REEs from process liquor feedstocks, maximising
recoverable value and revenue potential
Brazilian Critical Minerals Limited (ASX: BCM) (“BCM” or the “Company”) is pleased to report that an
initial bench scale test to enrich PLS solution and then individually extract the major rare earth elements
as high purity separated oxides has been successfully completed through the Rare Earth Technologies
Inc plant in Cincinnati, Ohio.
Figure 1. RETi chromatograph showing clear peaks of concentrated separated rare earth elements of
high purity which could be delivered to market. Minimum purity achieved was 99.9%.
ASX Announcement
Released 12th January 2026
https://braziliancriticalminerals.com/
Investor Hub: signup here
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: MINERAÇÃO BBX DO BRASIL LTDA, Rua dos Inconfidentes n⁰ 867, Savassi, Belo Horizonte, Minas Gerais, CEP 30.140-128
Page | 2
Andrew Reid, Managing Director, commented:
“The RETi bench-scale test indicated the technology is capable of achieving up to a 200× upgrade from
feed to product, delivering cleanly separated rare earth oxides with minimal impurity carryover in a
single processing route.
RETi has developed this proprietary separation and purification technology for rare-earth elements
utilising 100% environmentally safe, non-toxic solvents and proprietary column chemistry able to
achieve very high purity (up to ~99.999%) with a system designed to be cleaner and faster than other
traditional methods.
This process further adds to the already high ESG credentials of the Ema ISR project and BCM plans
further additional testwork to determine potential scale, commercial applicability an independent
validation in 2026.”
Steve Levin, RETI President & COO, commented:
“The BCM PLS solution is an excellent candidate for RETI’s two midstream rare earth processing
solutions, demonstrating the ability to deliver highly purified light and heavy rare earth elements to the
marketplace. The successful upgrading of the BCM PLS liquor via RETI’s solid phase extraction technology
favourably indicates scaling to the next step, pilot-scale extraction.
Output will be separated on RETI’s tonne-scale high-performance liquid chromatography (HPLC)
process, which has been operational since August 2024. We look forward to rapidly, yet conservatively,
expanding scale with BCM with the goal of sending light and heavy rare earths to the marketplace.”
To view the video of MD, Andrew Reid, discussing this announcement, click on the link below
https://braziliancriticalminerals.com/link/eW3wAe
Comments on Results
The Company recently sent a small 20l sample of PLS to RETi in the US for testing through their
proprietary technology. The PLS averaged 930 ppm total rare earth oxides (TREO), with approximately
50% of the solution being processed through this first phase of testing.
RETi’s proprietary Cerium (Ce) depletion protocol removed 99.4% of Ce as the first step followed by
significant enrichment or elution of the remaining REE’s into minimal acid volume achieving a 200x
concentration, resulting in a grade of 186,000ppm (18.6%) TREO-Ce.
This resulted in recoveries of near-total REE capture from the liquor, but where also highly selective and
effective in the rejection of alkali/alkaline-earth impurities (e.g. Magnesium). This process is highly
efficient, faster, with fewer steps, and lower energy/chemical consumption compared to traditional
methods.
ASX Announcement
Released 12th January 2026
https://braziliancriticalminerals.com/
Investor Hub: signup here
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: MINERAÇÃO BBX DO BRASIL LTDA, Rua dos Inconfidentes n⁰ 867, Savassi, Belo Horizonte, Minas Gerais, CEP 30.140-128
Page | 3
About the Technology
RETi’s environmentally responsible technology integrates Solid-Phase Extraction (SPE) and High-
Performance Liquid Chromatography (HPLC) to extract, separate, and purify rare-earth elements (REEs).
The proprietary SPE sorbent selectively extracts REEs at parts-per-million levels, remaining inert to non-
REEs and impurities, enabling both group extraction and enrichment.
HPLC then uses proprietary column chemistry to separate individual REEs based on subtle differences in
their interactions within the column, achieving high purity. The process uses mineral acid as the eluent,
eliminating the need for toxic, flammable organic solvents and providing significant environmental and
safety benefits. The method can also be optimized to isolate specific REEs, streamlining the separation
process.
This announcement has been authorised for release by the Board of Directors.
Enquiries
For more information please contact:
Andrew Reid
Managing Director
Brazilian Critical Minerals Limited
Andrew.reid@braziliancriticalminerals.com
Brazilian Critical Minerals Limited (BCM) is a mineral
exploration company listed on the Australian
Securities Exchange.
Its major exploration focus is Brazil, in the Apuí
region, where BCM has discovered a world class Ionic
Adsorbed Clay (IAC) Rare Earth Elements deposit. The
Ema IAC project is contained within the 781 km² of
exploration tenements within the Colider Group and
adjacent sediments.
BCM has defined an indicated and inferred MRE of
943Mt of REE’s with metallurgical recoveries
averaging 68% MREO, representing some of the
highest for these types of deposits anywhere in the
world.
The Company has commenced a bankable feasibility
study due for completion in Q1 2026, is engaging with
regulators regarding permitting approvals and has
ASX Announcement
Released 12th January 2026
https://braziliancriticalminerals.com/
Investor Hub: signup here
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: MINERAÇÃO BBX DO BRASIL LTDA, Rua dos Inconfidentes n⁰ 867, Savassi, Belo Horizonte, Minas Gerais, CEP 30.140-128
Page | 4
commenced a resource extension drilling program
which will inform the BFS economic analysis.
Ema REE Global Mineral Resource Estimate @COG 500ppm TREO
JORC
Category
cut-off
ppm TREO
Tonnes
Mt
TREO
ppm
NdPr
ppm
DyTb
ppm
MREO
ppm
MREO: TREO
%
Indicated 500 248 759 176 16 192 25
Inferred 500 695 701 165 16 181 26
Total 500 943 716 168 16 184 26
The information in this announcement relates to previously reported exploration results and mineral
resource estimates for the Ema Project released by the Company to ASX on 22 May 2023, 17 July 2023,
19 July 2023, 31 July 2023, 13 Sep 2023, 19 Oct 2023, 06 Dec 2023, 06 Feb 2024, 22 Feb 2024, 13 Mar
2024, 02 Apr 2024, 08 Oct 2024 19 Nov 2024, 21 Jan 2025, 17th
Feb 2025, 26th
Feb 2025, 10th
March
2025, 13th
March 2025, 28th
April 2025, 27th
May 2025, 28th
May, 13 June 2025, 01 July 2025, 18 August
2025, 01 Sep 2025, 22 Sep 2025, 20 Oct 2025, 23 Oct 2025, 01 Dec 2025, and 17 Dec 2025. The Company
confirms that is not aware of any new information or data that materially affects the information
included in the above-mentioned releases and CONTINUES TO APPLY and have not materially changed
in accordance with listing Rule 5.23.2.
Competent Person Statement
The scientific and technical information that relates to process metallurgy is based on information
reviewed by Mr Andrew Reid (Managing Director and CEO) of Brazilian Critical Minerals Pty Ltd. Mr
Hazelden is a Fellow of the AusIMM and has sufficient experience relevant to hydrometallurgical
processes to qualify as a Competent Person as defined by the JORC Code. Mr Reid owns shares in the
Company and participates in the Company’s employee securities incentive plan. Mr Reid consents to the
inclusion in this announcement of the matters based on their information in the form and context in
which it appears.
ASX Announcement
Released 12th January 2026
https://braziliancriticalminerals.com/
Investor Hub: signup here
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: MINERAÇÃO BBX DO BRASIL LTDA, Rua dos Inconfidentes n⁰ 867, Savassi, Belo Horizonte, Minas Gerais, CEP 30.140-128
Page | 5
Appendix 1
The following Table and Sections are provided to ensure compliance with JORC Code (2012 Edition).
JORC (2012) Table 1 – Section 1: Sampling Techniques and Data for auger hole drilling
Item JORC code explanation Comments
Sampling
Techniques
• Nature and quality of sampling (eg cut
channels. random chips. or specific
specialised industry standard
measurement tools appropriate to the
minerals under investigation. such as
down hole gamma sondes. or handheld
XRF instruments. etc). These examples
should not be taken as limiting the broad
meaning of sampling.
• Include reference to measures taken to
ensure sample representativity and the
appropriate calibration of any
measurement tools or systems used.
• Aspects of the determination of
mineralisation that are Material to the
Public Report.
• In cases where ‘industry standard’ work
has been done this would be relatively
simple (eg ‘reverse circulation drilling was
used to obtain 1 m samples from which 3
kg was pulverised to produce a 30 g charge
for fire assay’). In other cases more
explanation may be required. such as
where there is coarse gold that has
inherent sampling problems. Unusual
commodities or mineralisation types (eg
submarine nodules) may warrant
disclosure of detailed information.
• Exploration results are based on auger drilling conducted by BCM´s
exploration team.
• The data presented is based on the assay of soils and saprolite by
auger drilling at 1m sample intervals.
• Sampling was supervised by a GE21 geologist or a GE21 field
assistant.
• Every 1-metre sample was collected in a big plastic bag in the field
and transported to the exploration shed to be dried in the muffle.
prior to homogenisation.
• Samples were homogenised and subsequently riffle split with about
1 kg sent to SGS for analysis and a similar amount stored.
• 1 certified blank sample. 1 certified reference material (standard)
samples and 1 field duplicate sample were inserted into the sample
sequence for each 25 samples.
Drilling
Techniques
• Drill type (eg core. reverse circulation.
open-hole hammer. rotary air blast. auger.
Bangka. sonic. etc) and details (eg core
diameter. triple or standard tube. depth of
diamond tails. face-sampling bit or other
type. whether core is oriented and if so. by
what method. etc).
• Auger drilling was completed by a hand held-mechanical auger with
a 3” auger bit. The drilling is an open hole. meaning there is a
significant chance of contamination from surface and other parts of
the auger hole. Holes are vertical and not oriented.
Drill Sample
Recovery
• Method of recording and assessing core
and chip sample recoveries and results
assessed.
• Measures taken to maximise sample
recovery and ensure representative
nature of the samples.
• Whether a relationship exists between
sample recovery and grade and whether
sample bias may have occurred due to
preferential loss/gain of fine/coarse
material.
• No recoveries are recorded.
• The operator observes the volume of each metre and notes any
discrepancy.
• No relationship is believed to exist between recovery and grade.
ASX Announcement
Released 12th January 2026
https://braziliancriticalminerals.com/
Investor Hub: signup here
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: MINERAÇÃO BBX DO BRASIL LTDA, Rua dos Inconfidentes n⁰ 867, Savassi, Belo Horizonte, Minas Gerais, CEP 30.140-128
Page | 6
Item JORC code explanation Comments
Logging
• Whether core and chip samples have been
geologically and geotechnically logged to a
level of detail to support appropriate
Mineral Resource estimation. mining
studies and metallurgical studies.
• Whether logging is qualitative or
quantitative in nature. Core (or costean.
channel. etc) photography.
• The total length and percentage of the
relevant intersections logged.
• All holes were logged by GE21 geologist. detailing the colour.
weathering. alteration. texture and any geological observations.
Care is taken to identify transported cover from in-situ
saprolite/clay zones and the moisture content. Logging was done to
a level that would support a Mineral Resource Estimate.
• Qualitative logging with systematic photography of the stored box.
• The entire auger hole is logged.
Sub-
Sampling
Techniques
and
Sampling
Procedures
• If core. whether cut or sawn and whether
quarter. half or all core taken.
• If non-core. whether riffled. tube sampled.
rotary split. etc and whether sampled wet
or dry.
• For all sample types. the nature. quality
and appropriateness of the sample
preparation technique.
• Quality control procedures adopted for all
sub-sampling stages to maximise
representativity of samples.
• Measures taken to ensure that the
sampling is representative of the in-situ
material collected. including for instance
results for field duplicate/second-half
sampling.
• Whether sample sizes are appropriate to
the grain size of the material being
sampled.
• Auger sampling procedure is completed in the exploration shed in
Apui.
• The entire one metre sample is bagged on site. in a big plastic bag
which is transported to the exploration shed. where it is dried at
70-90C prior to homogenisation. then quartered to about 1kg to go
to SGS and another 1kg to store on site.
• Sample preparation for the auger samples was conducted at SGS
Vespasiano (greater Belo Horizonte) comprising oven drying at
100C. crushing of entire sample to 75% < 3mm followed by rotary
splitting and pulverisation of 250 to 300 grams at 95% minus 150#
• The <3mm rejects and the 250-300 grams pulverised sample were
returned to BCM for storage.
• Only the last 10 metres of each hole were sent to assay. the
samples above will be send if required.
Quality of
Assay Data
and
Laboratory
Tests
• The nature. quality and appropriateness of
the assaying and laboratory procedures
used and whether the technique is
considered partial or total.
• For geophysical tools. spectrometers.
handheld XRF instruments. etc. the
parameters used in determining the
analysis including instrument make and
model. reading times. calibrations factors
applied and their derivation. etc.
• Nature of quality control procedures
adopted (eg standards. blanks. duplicates.
external laboratory checks) and whether
acceptable levels of accuracy (ie lack of
bias) and precision have been established
RETI upgraded the PLS to produce a Mixed Rare Earth Solution by
selectively extracting and enriching REEs. Chromatographic separation
then yielded high-purity individual Rare earth Oxides (REOs),
supporting the development of the final demonstration and marketing
product.
• The process for producing a Mixed Rare Earth solution and
subsequently high-purity individual Rare Earth Oxides (REOs)
consists of the following sequential steps:
• RETI selectively extracts REEs as a group from the PLS using its
proprietary Solid Phase Extraction (SPE) sorbent.
• REEs are quantitatively recovered from the loaded sorbent using a
small acid volume, resulting in approximately 200-fold enrichment
of REE concentration.
• RETI chromatographically separates individual REEs using its
proprietary column chemistry.
• High-temperature calcination of REE salts yields high-purity
individual REOs, with purities approaching 99.99%.
ASX Announcement
Released 12th January 2026
https://braziliancriticalminerals.com/
Investor Hub: signup here
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: MINERAÇÃO BBX DO BRASIL LTDA, Rua dos Inconfidentes n⁰ 867, Savassi, Belo Horizonte, Minas Gerais, CEP 30.140-128
Page | 7
Item JORC code explanation Comments
Field Samples:
• 1 blank sample. 1 certified reference material (standard) sample
and 1 field duplicate sample were inserted by BBX into each 25-
sample sequence.
• Standard laboratory QA/QC procedures were followed. including
inclusion of standard. duplicate and blank samples.
• The assay results of the standards fall within acceptable tolerance
limits and no material bias is evident.
• The assay technique used for REE was Lithium Metaborate Fusion
ICP-MS (SGS code ICP95A and IMS95A). This is a recognised industry
standard analysis technique for REE suite and associated elements.
Elements analysed at ppm levels:
Ba Ce Cr Cs Dy Er Eu Ga
Gd Hf Ho La Lu Nb Nd Pr
Rb Sm Sn Sr Ta Tb Th Tm
U V W Y Yb Zr Zn Co
Cu Ni
The sample preparation and assay techniques used are industry
standard and provide total analysis.
The ICP95A reports the major elements oxides used to calculate
the Chemical Index of Alteration (CIA) at % levels included:
Al2O3 CaO Cr2O3 F2O3
K2O MgO MnO Na2O
P2O5 SiO2 TiO2
• The SGS laboratory used for the RRE assays is ISO 9001 and 14001
and 17025 accredited.
• Analytical standard for REE ITAK-713 and 714 were used as CRM
material in the batches sent to SGS.
• The assay results for the standards were consistent with the
certified levels of accuracy and precision and no bias is evident.
• The blanks used contain some REE. with critical elements Ce. Nd.
Dy and Y present in small quantities.
• Duplicate samples were allocated separate sample numbers and
submitted with the same analytical batch as the primary sample.
Variability between duplicate results is considered acceptable and
no sampling bias is evident.
• Laboratory inserted standards. blanks and duplicates were
analysed as per industry standard practice. There is no evidence of
bias from these results.
Verification
of Sampling
and Assaying
• The verification of significant intersections
by either independent or alternative
company personnel.
• The use of twinned holes.
• Documentation of primary data. data
entry procedures. data verification. data
storage (physical and electronic)
protocols.
• Apart from the routine QA/QC procedures by the Company and the
laboratory. there was no other independent or alternative
verification of sampling and assaying procedures.
• Analytical results for REE were supplied digitally. directly from the
SGS laboratory in Vespasiano to the BCMs Exploration Manager in
Rio de Janeiro.
• No twinned holes were used.
ASX Announcement
Released 12th January 2026
https://braziliancriticalminerals.com/
Investor Hub: signup here
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: MINERAÇÃO BBX DO BRASIL LTDA, Rua dos Inconfidentes n⁰ 867, Savassi, Belo Horizonte, Minas Gerais, CEP 30.140-128
Page | 8
Item JORC code explanation Comments
• Discuss any adjustment to assay data. • Geological data was logged onto paper and transferred to Excel
spreadsheets at end of the day and then transferred into the drill
hole database. Microsoft Access is used for database storage and
management and incorporates numerous data validation and data
integrity checks. All assay data is imported directly into the
Microsoft Access database.
• No adjustments were made to the data.
• All REE assay data received from the laboratory in element form is
unadjusted for data entry.
• Conversion of elements analysis (REE) to stoichiometric oxide (REO)
was undertaken by spreadsheet using defined conversion factors.
(Source:https://www.jcu.edu.au/advanced-analytical-
centre/resources/element-to-stoichiometric-oxide-conversion-
factors).
Element ppm Conversion Factor Oxide Form
Ce 1.2284 CeO2
Dy 1.1477 Dy2O3
Er 1.1435 Er2O3
Eu 1.1579 Eu2O3
Gd 1.1526 Gd2O3
Ho 1.1455 Ho2O3
La 1.1728 La2O3
Lu 1.1371 Lu2O3
Nd 1.1664 Nd2O3
Pr 1.2082 Pr6O11
Sm 1.1596 Sm2O3
Tb 1.1762 Tb4O7
Tm 1.1421 Tm2O3
Y 1.2699 Y2O3
Yb 1.1387 Yb2O3
Rare earth oxide is the industry accepted form for reporting rare
earths. The following calculations are used for compiling REO into
their reporting and evaluation groups:
TREO (Total Rare Earth Oxide) = La2O3 + CeO2 + Pr6O11 + Nd2O3
+ Sm2O3 + Eu2O3 + Gd2O3 + Tb4O7 + Dy2O3 + Ho2O3 + Er2O3 +
Tm2O3 + Yb2O3 + Y2O3 + Lu2O3
LREO (Light Rare Earth Oxide) = La2O3 + CeO2 + Pr6O11 + Nd2O3
HREO (Heavy Rare Earth Oxide) = Sm2O3 + Eu2O3 + Gd2O3 +
Tb4O7 + Dy2O3 + Ho2O3 + Er2O3 + Tm2O3 + Yb2O3 + Y2O3 +
Lu2O3
CREO (Critical Rare Earth Oxide) = Nd2O3 + Eu2O3 + Tb4O7 +
Dy2O3 + Y2O3
(From U.S. Department of Energy. Critical Material Strategy.
December 2011)
MREO (Magnetic Rare Earth Oxide) = Nd2O3 + Pr6O11 + Tb4O7 +
Dy2O3
NdPr = Nd2O3 + Pr6O11
DyTb = Dy2O3 + Tb4O7
In elemental from the classifications are:
ASX Announcement
Released 12th January 2026
https://braziliancriticalminerals.com/
Investor Hub: signup here
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: MINERAÇÃO BBX DO BRASIL LTDA, Rua dos Inconfidentes n⁰ 867, Savassi, Belo Horizonte, Minas Gerais, CEP 30.140-128
Page | 9
Item JORC code explanation Comments
TREE: La+Ce+Pr+Nd+Sm+Eu+Gd+Tb+Dy+Ho+Er+Tm+Tb+Lu+Y
HREE: Sm+Eu+Gd+Tb+Dy+Ho+Er+Tm+Tb+Lu+Y
CREE: Nd+Eu+Tb+Dy+Y
LREE: La+Ce+Pr+Nd
Location of
Data Points
• Accuracy and quality of surveys used to
locate drill holes (collar and down-hole
surveys). trenches. mine workings and
other locations used in Mineral Resource
estimation.
• Specification of the grid system used.
• Quality and adequacy of topographic
control.
• The UTM WGS84 zone 21S grid datum is used for current reporting.
The drill holes collar coordinates for the holes reported are
currently controlled by hand-held GPS.
Data Spacing
and
Distribution
• Data spacing for reporting of Exploration
Results.
• Whether the data spacing and distribution
is sufficient to establish the degree of
geological and grade continuity
appropriate for the Mineral Resource and
Ore Reserve estimation procedure(s) and
classifications applied.
• Whether sample compositing has been
applied.
• Auger holes were over 200m to 400m apart. designed for testing
iREE mineralization over the mapped felsic volcanics.
• The data spacing and distribution is sufficient to establish the level
of REE elements present in the target area and its continuity along
the regolith profile appropriate for a Mineral Resource.
• No sample composition was applied.
Orientation
of Data in
relation to
Geological
Structure
• Whether the orientation of sampling
achieves unbiased sampling of possible
structures and the extent to which this is
known. considering the deposit type.
• If the relationship between the drilling
orientation and the orientation of key
mineralised structures is considered to
have introduced a sampling bias. this
should be assessed and reported if
material.
• The location and depth of the sampling is appropriate for the
deposit type.
• Relevant REE values are compatible with the exploration model for
ionic REEs.
• No relationship between mineralisation and drilling orientation is
known at this stage.
Sample
security
• The measures taken to ensure sample
security.
• The auger samples in sealed plastic bags were sent directly to SGS
by bus and then airfreight. The Company has no reason to believe
that sample security poses a material risk to the integrity of the
assay data.
Audit or
Reviews
• The results of any audits or reviews of
sampling techniques and data.
• The sampling techniques and data have been reviewed by the
Competent Person and are found to be of industry standard.
ASX Announcement
Released 12th January 2026
https://braziliancriticalminerals.com/
Investor Hub: signup here
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: MINERAÇÃO BBX DO BRASIL LTDA, Rua dos Inconfidentes n⁰ 867, Savassi, Belo Horizonte, Minas Gerais, CEP 30.140-128
Page | 10
JORC (2012) Table 1 - Section 2: Reporting of Exploration Results
Criteria JORC code explanation Commentary
Mineral
Tenement
and Land
Tenure Status
• Type. reference name/number. location
and ownership including agreements or
material issues with third parties such as
joint ventures. partnerships. overriding
royalties. native title interests. historical
sites. wilderness or national park and
environmental settings.
• The security of the tenure held at the time
of reporting along with any known
impediments to obtaining a licence to
operate in the area.
• The EMA and EMA EAST leases are 100% owned by
BCM with no issues in respect to native title
interests. historical sites. wilderness or national
park and environmental settings.
• The company is not aware of any impediment to
obtain a licence to operate in the area.
Exploration
done by Other
Parties
• Acknowledgment and appraisal of
exploration by other parties.
• No exploration by other parties has been
conducted in the region.
Geology
• Deposit type. geological setting and style of
mineralisation.
• The REE mineralisation at EMA is contained within
the tropical lateritic weathering profile developed
on top of felsic rocks. rhyolites as per the Chinese
deposits.
• The REE mineralisation is concentrated in the
weathered profile where it has dissolved from the
primary mineral. such as monazite and xenotime.
then adsorbed on to the neo-forming fine particles
of aluminosilicate clays (e.g. kaolinite. illite.
smectite).
• This adsorbed iREE is the target for extraction and
production of REO.
Drill Hole
Information
• A summary of all information material to
the understanding of the exploration results
including a tabulation of the following
information for all Material drill holes:
• easting and northing of the drill
hole collar
• elevation or RL (Reduced Level –
elevation above sea level in
metres) of the drill hole collar
• dip and azimuth of the hole
• down hole length and
interception depth
• hole length.
• If the exclusion of this information is
justified on the basis that the information is
not Material and this exclusion does not
detract from the understanding of the
report. the Competent Person should
clearly explain why this is the case.
• Auger locations and diagrams are presented in this
announcement.
• Details are tabulated in the announcement.
ASX Announcement
Released 12th January 2026
https://braziliancriticalminerals.com/
Investor Hub: signup here
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: MINERAÇÃO BBX DO BRASIL LTDA, Rua dos Inconfidentes n⁰ 867, Savassi, Belo Horizonte, Minas Gerais, CEP 30.140-128
Page | 11
Criteria JORC code explanation Commentary
Data
aggregation
methods
• In reporting Exploration Results. weighting
averaging techniques. maximum and/or
minimum grade truncations (eg cutting of
high grades) and cut-off grades are usually
Material and should be stated.
• Where aggregate intercepts incorporate
short lengths of high-grade results and
longer lengths of low-grade results. the
procedure used for such aggregation should
be stated and some typical examples of
such aggregations should be shown in
detail.
• The assumptions used for any reporting of
metal equivalent values should be clearly
stated.
• Weighted averages were calculated for all
intercepts.
• 500ppm TREO cut-off grade was applied to define
the relevant intersections.
• No metal equivalent values reported.
Relationship
between
mineralization
widths and
intercepted
lengths
• These relationships are particularly
important in the reporting of Exploration
Results.
• If the geometry of the mineralisation with
respect to the drill hole angle is known. its
nature should be reported.
• If it is not known and only the down hole
lengths are reported. there should be a
clear statement to this effect (eg ‘down hole
length. true width not known’).
• Significant values of REE were reported for the
auger samples.
• Mineralisation orientation is not known at this
stage. although assumed to be flat.
• The downhole depths are reported. true widths
are not known at this stage.
Diagrams
• Appropriate maps and sections (with scales)
and tabulations of intercepts should be
included for any significant discovery being
reported These should include. but not be
limited to a plan view of drill hole collar
locations and appropriate sectional views.
• Maps and tables of the soil auger holes location
and target location are inserted.
Balanced
reporting
• Where comprehensive reporting of all
Exploration Results is not practicable.
representative reporting of both low and
high grades and/or widths should be
practiced to avoid misleading reporting of
Exploration Result
Share your feedback
Discover