Ema Project Achieves Low Impurities
Released
Released
Announcement PDF
ASX Announcement
Released 2nd August 2024
FINAL DESORPTION SLURRY RESULTS FOR
EMA RARE EARTH PROJECT
VERY LOW IMPURITIES
Highlights
•
Final ANSTO optimised slurry leach assays have resulted in very low impurities:
o
o
o
o
o
o
Uranium
= 0.2 mg/l
Thorium
= 0.02 mg/l
Aluminium = 73 mg/l
Iron
= <1 mg/l
Calcium
= 11 mg/l, and
Silica
= 6 mg/l
•
Slurry desorption tests were completed on the Ema project master composite, 50 kg of material
collected from 12 holes and 62 samples3 to mimic a tank leaching project setup
•
These results are a key step to achieving low impurities in the final product Mixed Rare Earth
Carbonate (MREC)
•
Final process steps of impurity removal then precipitation of REEs from solution to make the
MREC have commence at ANSTO
•
Slurry desorption results were achieved using standard weak 0.3 M ammonium sulfate leaching
solution, pH 4.5, at ambient temperature, short leach times of only 30 minutes duration with a
solid density of 40 wt%
•
Four exploration auger rigs have commenced operating within the Ema central high-grade zone,
over a 12-week program with first results expected during August
•
Scoping Study and re-commencement of environmental baseline studies in final negotiation
Andrew Reid, Managing Director, commented:
“These results confirm BCM finds itself in the enviable position, after having completed a suite of tests under
differing conditions with different reagents, that the Ema mineralisation has a fairly large window of conditions
where rare earth recoveries and impurity concentrations are similar.
The unique characteristics of Ema means that BCM can now evaluate different processing strategies such as heap
leaching and in-situ leaching on its journey towards a low CAPEX practical project solution that is tailored towards
the current rare earth market and does not require pricing levels which are 2 or 3 times current spot levels as most
projects now need. Testwork programs to prove these alternative process strategies have commenced.
The current drilling program is progressing smoothly and we expect to kick start the scoping study very shortly as
we bed down the final criteria which will be used as the basis for the assessment“.
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
ASX Announcement
Released 2nd August 2024
Brazilian Critical Minerals Limited (ASX: BCM) (“BCM” or the “Company”) is pleased to provide an
update on work programs from Australia’s Nuclear Science and Technology Organisation (ANSTO) with
respect to the Ema Rare Earths Project which hosts an Inferred Mineral Resource1 of 1.02Bt @ 793ppm
TREO.
Work being undertaken by ANSTO over the last several months has resulted in very high recoveries of
NdPr2 as was announced on the 7th May 2024. ANSTO has now reported the final slurry leach test results
which confirm very low concentrations of deleterious or impurity elements.
Table 1. Impurity values following optimised testing and leaching of Ema master composite sample.
Uranium
Thorium
Aluminium
Iron
Calcium
Silica
mg/l
0.2
0.02
73
<1
11
6
Impurity Levels
Impurities affect REE recovery and precipitation efficiencies and are therefore a vital component of the
process to understand. Control of the most troublesome impurities (Al, Fe, Th, U) depends on their
concentration and the degree of purity required in MREC.
Figure 1. Key steps in the process flow sheet for ionic clay MREC production. REE Leaching section
highlighted represents stage of processing where results from Table 1. above were sourced.
The Company is now confident that these low uranium and thorium values can be removed through
simple pH adjustment during the next stage of impurity removal leading to a final MREC product that
meets European, North American and Asian offtake partners for specification testing to advance
discussions regarding commercial offtake.
References
1
Brazilian Critical Minerals (ASX:BCM) ASX Announcement “Massive Maiden Mineral Resource Estimate
for Ema Project 22.04.24
2
Brazilian Critical Minerals (ASX:BCM) ASX Announcement “ World Leading Recoveries Confirmed at
Ema Project 07.05.24
3
Brazilian Critical Minerals (ASX:BCM) ASX Announcement “World Class REE Recoveries at Ema project”
13.03.24
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
ASX Announcement
Released 2nd August 2024
Competent Person Statement
The information in this report that relates to exploration results released by the Company to the ASX on
2 April, 22 April, 3 May and 7 May 2024 is based on information compiled by Mr. Antonio de Castro, BSc
(Hons), MAusIMM, CREA, who acts as BCM´s Senior Consulting Geologist through the consultancy firm,
ADC Geologia Ltda. Mr. de Castro has sufficient experience which is relevant to the type of deposit under
consideration and to the reporting of exploration results and analytical and metallurgical test work to
qualify as a competent person as defined in the 2012 Edition of the Joint Ore Reserves Committee (JORC)
“Australasian Code for Reporting of Exploration Results, Mineral Resources and Ore Reserves”. Mr.
Castro consents to the report being issued in the form and context in which it appears.
The Company confirms that it is not aware of any new information or data that materially affects the
information included in the relevant market announcement and, in the case of mineral resource
estimate, that all material assumptions and technical parameters underpinning the estimates in the
relevant market announcement continue to apply and have not materially changed. Refer to ASX
announcement dated 22 April 2024.
About Brazilian Critical Minerals Ltd
Brazilian Critical Minerals Limited (BCM) is a mineral
exploration company listed on the Australian
Securities Exchange.
Its major exploration focus is Brazil, in the Apuí
region, where BCM has discovered a world class Ionic
Adsorbed Clay (IAC) Rare Earth Elements deposit. The
Ema IAC project is contained within the 781 km² of
exploration tenements within the Colider Group.
BCM has defined an inferred MRE of 1.02Bt of REE’s
with metallurgical recoveries averaging 68% MREO
some of the highest for these types of deposits
anywhere in the world.
The Company is currently converting this MRE from
Inferred into the Indicated category with an extensive
drill program which will inform the scoping study and
economic analysis due for completion in late 2024.
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
ASX Announcement
Released 2nd August 2024
Appendix 4
The following Table and Sections are provided to ensure compliance with JORC Code (2012
Edition).
JORC (2012) Table 1 – Section 1: Sampling Techniques and Data for auger hole drilling
Item
JORC code explanation
Comments
Sampling
Techniques
• Nature and quality of
sampling (eg cut channels,
random chips, or specific
specialised
industry
standard
measurement
tools appropriate to the
minerals
under
investigation, such as down
hole gamma sondes, or
handheld XRF instruments,
etc). These examples should
not be taken as limiting the
broad meaning of sampling.
• Metallurgical results are for a 49.6 kg composite
sample of 12 auger holes, from the drilling conducted
by BCM´s exploration team during 2023, conducted at
ANSTO, Sydney, Australia.
• 0.8 kg of the homogenized sample from each interval,
was used to make the composite.
• The preparation of the composite was supervised by a
BCM geologist.
• Holes were sampled using a powered auger drill (open
hole) conducted by BCM´s exploration team.
• Include
reference
to
measures taken to ensure
sample representativity and
the appropriate calibration
of any measurement tools
or systems used.
• Aspects
of
the
determination
of
mineralisation that are
Material to the Public
Report.
• Sampling was supervised by a BCM geologist or field
assistants.
• Every 1-metre sample was collected in a raffia bag in
the field and transported to the exploration shed to be
dried in the sun, prior to homogenisation.
• Samples were homogenised and subsequently riffle
split with about 1 kg sent to SGS for preparation and
analysis and a similar amount stored on site.
• 1 certified blank sample. 1 certified reference material
(standard) samples and 1 field duplicate sample were
inserted into the sample sequence for each 25 samples.
• In cases where ‘industry
standard’ work has been
done this would be
relatively
simple
(eg
‘reverse circulation drilling
was used to obtain 1 m
samples from which 3 kg
was pulverised to produce a
30 g charge for fire assay’).
In other cases more
explanation
may
be
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
ASX Announcement
Released 2nd August 2024
Item
JORC code explanation
Comments
required, such as where
there is coarse gold that has
inherent
sampling
problems.
Unusual
commodities
or
mineralisation types (eg
submarine nodules) may
warrant
disclosure
of
detailed information.
Drilling
Techniques
Drill
Sample
Recovery
• Drill type (eg core, reverse
circulation,
open-hole
hammer, rotary air blast,
auger, Bangka, sonic, etc)
and details (eg core
diameter, triple or standard
tube, depth of diamond
tails, face-sampling bit or
other type, whether core is
oriented and if so, by what
method, etc).
• Auger drilling was completed by a hand held
mechanical auger with a 3” auger bit. The drilling is an
open hole, meaning there is a significant chance of
contamination from surface and other parts of the
auger hole. Holes are vertical and not oriented.
• Method of recording and
assessing core and chip
sample recoveries and
results assessed.
• No recoveries are recorded.
• Measures
taken
to
maximise sample recovery
and ensure representative
nature of the samples.
• The maximum depth achieved with the powered auger
was 31m, and this was only achievable if the hole did
not encounter fragments of rocks/boulders etc. sitting
within the weathered profile, and/or the water table.
Final depths were recorded accordingly to the length of
the rods in the hole.
• The operator observes the volume of each metre and
notes any discrepancy.
• When recovery is below 75% in two sequential one
metre interval, the field crew stops the drill hole.
• No relationship is believed to exist between recovery
and grade.
• Whether a relationship
exists between sample
recovery and grade and
whether sample bias may
have occurred due to
preferential loss/gain of
fine/coarse material.
Logging
• Whether core and chip
samples
have
been
geologically
and
geotechnically logged to a
level of detail to support
appropriate
Mineral
Resource
estimation,
mining
studies
and
metallurgical studies.
• All holes were logged by BCM geologists or field
technicians, detailing the colour, weathering,
alteration, texture and any geological observations.
Care is taken to identify transported cover from in-situ
saprolite/clay zones and the moisture content. Logging
was done to a level that would support a Mineral
Resource Estimate.
• Qualitative logging with systematic photography of the
stored box.
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
ASX Announcement
Released 2nd August 2024
Item
JORC code explanation
• Whether
logging
is
qualitative or quantitative
in nature. Core (or costean,
channel, etc) photography.
Comments
• The entire auger hole is logged.
• The total length and
percentage of the relevant
intersections logged.
SubSampling
Techniques
and
Sampling
Procedures
• If core, whether cut or sawn
and whether quarter, half
or all core taken.
• If non-core, whether riffled,
tube sampled, rotary split,
etc and whether sampled
wet or dry.
• For all sample types, the
nature,
quality
and
appropriateness of the
sample
preparation
technique.
• Quality control procedures
adopted for all subsampling
stages
to
maximise representativity
of samples.
• Measures taken to ensure
that the sampling is
representative of the in-situ
material
collected,
including
for
instance
results
for
field
duplicate/second-half
sampling.
• Whether sample sizes are
appropriate to the grain size
of the material being
sampled.
• The homogenised sample was screened/crushed to
100% passing 1 mm and rotary split into representative
portions for head assay, screening and desorption
testing. Samples for head assay and desorption testing
were pulverised.
• The composite sample was prepared in the Apui
exploration facility with 0.8 kg of each mineralized
interval previously homogenized from 12 auger holes,
then homogenised and split in three plastic bags which
were then sealed prior to shipment to Catalão and then
to ANSTO by regular mail.
• The 0.8 kg sample size is adequate to represent each
individual samples in the composite.
• The homogenised sample was screened/crushed to
100% passing 1 mm and rotary split into representative
portions for head assay, screening and desorption
testing. Samples for head assay and desorption testing
were pulverised.
• 6 aliquots used for the first diagnostic ammonium
sulfate leaching, under different parameters for the
ammonium sulfate concentration and pH, all for 2
hours in ambient temperature and pressure.
• Auger sampling procedure is completed in the
exploration shed in Apui.
• The entire one metre sample is bagged on site, in a
raffia bag which is transported to the exploration shed,
where it is naturally dried prior to homogenisation,
then quartered to about 1kg to go to SGS and another
1kg to store on site.
• The composite sample was from the 1 kg sample stored
on site.
• Sample preparation for the composite, such as
pulverization and homogenization of the 49.6 kg was
conducted at ANSTO.
• Sample preparation for the auger samples was
conducted at SGS Vespasiano (greater Belo Horizonte)
comprising oven drying, crushing of entire sample to
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
ASX Announcement
Released 2nd August 2024
Item
JORC code explanation
Comments
75% < 3 mm followed by rotary splitting and
pulverisation of 250 to 300 g at 95% minus 150#
• The <3 mm rejects and the 250-300 g pulverised
sample were returned to BCM for storage, after all
assays were reported.
Quality of
Assay Data
and
Laboratory
Tests
• The nature, quality and
appropriateness of the
assaying and laboratory
procedures
used
and
whether the technique is
considered partial or total.
• The assays for REE in the ammonium solution from the
• For geophysical tools,
spectrometers, handheld
XRF instruments, etc, the
parameters
used
in
determining the analysis
including instrument make
and model, reading times,
calibrations factors applied
and their derivation, etc.
•
• Nature of quality control
procedures adopted (eg
standards,
blanks,
duplicates,
external
laboratory checks) and
whether acceptable levels
of accuracy (ie lack of bias)
and precision have been
established
•
•
•
6 leaching tests and for the head grade were conducted
by ANSTO.
All data reported from ANSTO were in elemental form
including the TREY and presented in this
announcement as received.
ALS introduced its own QA/QC controls, incorporating
standards, blanks and duplicates.
The ALS method for analysis of REEs in solution was
ME-MS02 (ICP-MS) and for head assay was ME-MS81
(lithium tetraborate fusion digest/ICP-MS finish).
Gangue elements in solution were assayed by ICP-OES
at ANSTO and gangue elements in the head sample by
XRF at ANSTO.
1 blank sample. 1 certified reference material
(standard) sample and 1 field duplicate sample were
inserted by BCM into each 25-sample sequence.
• Standard laboratory QA/QC procedures were followed.
including inclusion of standard. duplicate and blank
samples.
• The assay results of the standards fall within acceptable
tolerance limits and no material bias is evident.
• The assay technique used for REE’s was lithium
tetaborate fusion / ICP-MS finish (SGS code ICP95A and
IMS95A). This is a recognised industry standard
analysis technique for REE suite and associated
elements. Elements analysed at ppm levels:
Ba Ce Co Cs Dy Er Eu Ga
Gd Hf Ho La Lu Nb Nd Pr
Rb Sm Sn Sr Ta Tb Th Tm
U
V
W Y
Yb Zr
Zn Co
Cu Ni
The sample preparation and assay techniques used
are industry standard and provide total analysis.
The ICP95A reports the major elements oxides used to
calculate the Chemical Index of Alteration (CIA) at %
levels:
Al2O3
CaO
Cr2O3
F2O3
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
ASX Announcement
Released 2nd August 2024
Item
JORC code explanation
Comments
K2O
MgO
MnO
P2O5
SiO2
TiO2
Na2O
• The SGS laboratory used for the RRE assays is ISO 9001
and 14001 and 17025 accredited.
• Analytical standard for REE ITAK-705 was used as CRM
material in the batches sent to SGS.
• The assay results for the standards were consistent
with the certified levels of accuracy and precision and
no bias is evident.
• The blanks used contain some REE. with critical
elements Ce. Nd. Dy and Y present in small quantities.
• Duplicate samples were allocated separate sample
numbers and submitted with the same analytical batch
as the primary sample. Variability between duplicate
results is considered acceptable and no sampling bias
is evident.
• Laboratory inserted standards. blanks and duplicates
were analysed as per industry standard practice. There
is no evidence of bias from these results.
Verification
of Sampling
and
Assaying
• The
verification
of
significant intersections by
either independent or
alternative
company
personnel.
• The use of twinned holes.
• Documentation of primary
data,
data
entry
procedures,
data
verification, data storage
(physical and electronic)
protocols.
• Discuss any adjustment to
assay data.
• No independent or alternative verification of sampling
and assaying procedures was carried out.
• The metallurgical report was sent directly to BCM´s MD
in Australia.
• Analytical results for REE were supplied digitally,
directly from the SGS laboratory in Vespasiano to
BCM’s Exploration Manager in Rio de Janeiro.
• No twinned holes were used.
• Geological data was logged onto paper and transferred
to Excel spreadsheets at end of the day and then
transferred into the drill hole database. Microsoft
Access is used for database storage and management
and incorporates numerous data validation and data
integrity checks. All assay data is imported directly into
the Microsoft Access database.
• No adjustments were made to the data.
• All REE assay data received from the laboratory in
element form is unadjusted for data entry.
• Conversion of elements analysis (REE) to stoichiometric
oxide (REO) was undertaken by spreadsheet using
defined
conversion
factors.
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
ASX Announcement
Released 2nd August 2024
Item
JORC code explanation
Comments
(Source:https://www.jcu.edu.au/advanced-analyticalcentre/resources/element-to-stoichiometric-oxideconversion-factors).
Element ppm
Conversion
Oxide Form
Factor
Ce
1.2284
CeO2
Dy
1.1477
Dy2O3
Er
1.1435
Er2O3
Eu
1.1579
Eu2O3
Gd
1.1526
Gd2O3
Ho
1.1455
Ho2O3
La
1.1728
La2O3
Lu
1.1371
Lu2O3
Nd
1.1664
Nd2O3
Pr
1.2082
Pr6O11
Sm
1.1596
Sm2O3
Tb
1.1762
Tb4O7
Tm
1.1421
Tm2O3
Y
1.2699
Y2O3
Yb
1.1387
Yb2O3
Rare earth oxide is the industry accepted form for
reporting rare earths. The following calculations are
used for compiling REO into their reporting and
evaluation groups:
TREO (Total Rare Earth Oxide) = La2O3 + CeO2 +
Pr6O11 + Nd2O3 + Sm2O3 + Eu2O3 + Gd2O3 + Tb4O7
+ Dy2O3 + Ho2O3 + Er2O3 + Tm2O3 + Yb2O3 + Y2O3 +
Lu2O3
LREO (Light Rare Earth Oxide) = La2O3 + CeO2 +
Pr6O11 + Nd2O3
HREO (Heavy Rare Earth Oxide) = Sm2O3 + Eu2O3 +
Gd2O3 + Tb4O7 + Dy2O3 + Ho2O3 + Er2O3 + Tm2O3 +
Yb2O3 + Y2O3 + Lu2O3
CREO (Critical Rare Earth Oxide) = Nd2O3 + Eu2O3 +
Tb4O7 + Dy2O3 + Y2O3
(From U.S. Department of Energy, Critical Material
Strategy, December 2011)
MREO (Magnetic Rare Earth Oxide) = Nd2O3 + Pr6O11
+ Tb4O7 + Dy2O3
NdPr = Nd2O3 + Pr6O11
DyTb = Dy2O3 + Tb4O7
In elemental from the classifications are:
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
ASX Announcement
Released 2nd August 2024
Item
JORC code explanation
Comments
TREE:
La+Ce+Pr+Nd+Sm+Eu+Gd+Tb+Dy+Ho+Er+Tm+Tb+Lu+Y
HREE: Sm+Eu+Gd+Tb+Dy+Ho+Er+Tm+Tb+Lu+Y
CREE: Nd+Eu+Tb+Dy+Y
LREE: La+Ce+Pr+Nd
Location of
Data Points
• Accuracy and quality of
surveys used to locate drill
holes (collar and down-hole
surveys), trenches, mine
workings
and
other
locations used in Mineral
Resource estimation.
• Auger collar locations were surveyed initially by GPS, at
an estimated accuracy of 2m.
• Specification of the grid
system used.
• The grid system used for all data types in a UTM
projection is SIRGAS Zone 21 Southern Hemisphere. No
local grids are used.
• Quality and adequacy
topographic control.
Data
Spacing
and
Distribution
• Data spacing for reporting
of Exploration Results.
• Whether the data spacing
and distribution is sufficient
to establish the degree of
geological
and
grade
continuity appropriate for
the Mineral Resource and
Ore Reserve estimation
procedure(s)
and
classifications applied.
• Whether
compositing
applied.
Orientation
of Data in
relation to
Geological
Structure
of
has
• Posterior to the end of the drilling campaign, the collar
locations were picked up by a licensed surveyor using a
Trimble total station (+/- 5cm), referenced to a
government survey point. All drill holes have been
checked spatially in 3D.
• The auger holes collar coordinates for the holes used in
the resource estimation were surveyed to subdecimetre accuracy by a licenced surveyor.
• Auger holes were over 200m to 800m apart, designed
for testing iREE mineralisation over the mapped felsic
volcanics.
• The data spacing and distribution is sufficient to
establish the level of REE elements present in the
target area and its continuity along the regolith profile
appropriate for a Mineral Resource.
• No sample composition was applied.
sample
been
• Whether the orientation of
sampling achieves unbiased
sampling
of
possible
structures and the extent to
which this is known,
considering the deposit
type.
• The location and depth of the sampling is appropriate
for the deposit type.
• Relevant REE values are compatible with the
exploration model for ionic REEs.
• No relationship between mineralisation and drilling
orientation is known at this stage.
• If the relationship between
the drilling orientation and
the orientation of key
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
ASX Announcement
Released 2nd August 2024
Item
JORC code explanation
Comments
mineralised structures is
considered
to
have
introduced a sampling bias,
this should be assessed and
reported if material.
Sample
security
• The measures taken to
ensure sample security.
• The auger samples in sealed plastic bags were sent
directly to SGS by bus and then airfreight. The Company
has no reason to believe that sample security poses a
material risk to the integrity of the assay data.
Audit or
Reviews
• The results of any audits or
reviews
of
sampling
techniques and data.
• The sampling techniques and data have been reviewed
by the Competent Person and are found to be of
industry standard.
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
ASX Announcement
Released 2nd August 2024
JORC (2012) Table 1 - Section 2: Reporting of Exploration Result
Criteria
Mineral
Tenement
and Land
Tenure Status
JORC code explanation
• Type, reference name/number,
location and ownership including
agreements or material issues with
third parties such as joint ventures,
partnerships, overriding royalties,
native title interests, historical
sites, wilderness or national park
and environmental settings.
• The security of the tenure held at
the time of reporting along with
any known impediments to
obtaining a licence to operate in
the area.
Commentary
• The Ema and Ema East leases are 100%
owned by BCM with no issues in respect
to native title interests, historical sites,
wilderness or national park and
environmental settings.
• The Company is not aware of any
impediment to obtain a licence to
operate in the area.
Exploration
done by Other
Parties
• Acknowledgment and appraisal of
exploration by other parties.
• Some non-listed entities have conducted
limited exploration in the region. No
results are publicly available.
Geology
• Deposit type, geological setting
and style of mineralisation.
• The REE mineralisation at Ema is
contained within the tropical lateritic
weathering profile developed on top of
felsic rocks (rhyolites), as per the
Chinese deposits.
• The REE mineralisation is concentrated
in the weathered profile where it has
dissolved from the primary mineral, such
as monazite and xenotime, then
adsorbed on to the neo-forming fine
particles of aluminosilicate clays (e.g.
kaolinite, illite, smectite).
• This adsorbed iREE is the target for
extraction and production of REO.
Drill Hole
Information
• A summary of all information
material to the understanding of
the exploration results including a
tabulation of the following
information for all Material drill
holes:
•
easting and northing of
the drill hole collar
•
elevation or RL (Reduced
Level – elevation above
sea level in metres) of the
drill hole collar
• Auger hole locations and diagrams are
presented in this announcement.
• Details
are
tabulated
announcement.
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
in
the
ASX Announcement
Released 2nd August 2024
Criteria
JORC code explanation
•
dip and azimuth of the
hole
•
down hole length and
interception depth
•
hole length.
Commentary
• If the exclusion of this information
is justified on the basis that the
information is not Material and this
exclusion does not detract from
the understanding of the report,
the Competent Person should
clearly explain why this is the case.
Data
aggregation
methods
• In reporting Exploration Results,
weighting averaging techniques,
maximum and/or minimum grade
truncations (eg cutting of high
grades) and cut-off grades are
usually Material and should be
stated.
• Weighted averages were calculated for
all intercepts and announced.
• No metal equivalent values reported.
• Where
aggregate
intercepts
incorporate short lengths of highgrade results and longer lengths of
low-grade results, the procedure
used for such aggregation should
be stated and some typical
examples of such aggregations
should be shown in detail.
• The assumptions used for any
reporting of metal equivalent
values should be clearly stated.
Relationship
between
mineralisation
widths and
intercepted
lengths
• These relationships are particularly
important in the reporting of
Exploration Results.
• If
the
geometry
of
the
mineralisation with respect to the
drill hole angle is known, its nature
should be reported.
• If it is not known and only the down
hole lengths are reported, there
should be a clear statement to this
effect (eg ‘down hole length, true
width not known’).
• Significant values of desorbed REE were
reported for the auger samples.
• Mineralisation orientation is not known
at this stage, although assumed to be
flat.
• The downhole depths are reported, true
widths are not known at this stage.
Brazilian Critical Minerals Ltd (ABN: 82 089 221 634)
AUS: Level 28, 140 St Georges Terrace, Perth WA 6000 T +61 8 6383 7820
BRA: Av Jornalista Riccardo Marinho, 360, Sala 113, Barra da Tijuca, Rio de Janeiro T +55 21 2439 57
ASX Announcement
Released 2nd August 2024
Criteria
JORC code explanation
Commentary
Diagrams
• Appropriate maps and sections
(with scales) and tabulations of
intercepts should be included for
any significant discovery being
reported These should include, but
not be limited to a plan view of drill
hole
collar
locations
and
appropriate sectional views.
• Maps and tables of the auger hole
location and target location are inserted.
Balanced
reporting
• Where comprehensive reporting of
all Exploration Results is not
practicable,
representative
reporting of both low and high
grades and/or widths should be
practiced to avoid misleading
reporting of Exploration Results.
• R
Share your feedback